Window Cleaning Resources
All that you need to succeed

This is a landing page
Please visit our main site

Products created by
Window Cleaning Resources

Software
Round Tracker v4 PRO - Customer Management System
Template Kits
Window Cleaning Business Templates and Stationery Kit
Health and Safety Documents Templates Kit
DVD’s
Window Cleaning Essentials DVD
Choosing and Using a Water Fed Pole System DVD
Advanced Window Cleaning Skills DVD


Home

Trade Suppliers Directory

Window Cleaning Rounds For Sale

Window Cleaner Directory

Tips, Articles, Advice

Equipment For Sale

Find Window Cleaning Work


Telescopic Pole Maintenance
Contributed by

Gardiner Pole Systems - Helpful Advice


“The pole is getting very hard to extend and retract -
How can I sort this out?”

Sometimes after a short while a new pole can start to be stiff to operate. This is because when they are new the tolerances are tighter on the poles so they are more sensitive to dirt, etc. Sometimes this phase passes after couple of weeks as a little wear eases this situation.

However sometimes a little help is needed:

The first thing to try is to slightly loosen the clamp adjusting nut a couple of clicks. These nuts turn the opposite way to usual.

If this doesn't make enough difference, fully extend the pole and direct a hose jet of water up the pole flushing out any dirt out, spray the jet in and around each clamp as well, then dry the pole off with a cloth and a little non-waxed based household polish. Some people do the above every week as a matter of course. Doing so will prolong the life of the pole as generally dirt and grit are the main wearing agents.

If this isn't enough, the pole can be quickly taken apart and flushed with water. To do this, undo the Allen nut on each clamp and remove the plastic retaining peg, open the lever and slide the clamp off of each section. Spray with a hose, each section fully, paying particular attention the white section guides. Dry it all off and if you wish apply a polish to it. Reassemble.

“My pole has started to slip when in use;
the clamps do not seem to hold anymore.
- How can I cure this?”

Your clamps will need constant adjustment during the life of your pole, just a few click turns of the clamp nut will often remedy the situation. Remember that this nut turns the opposite way to usual.

If your clamps have worn too much you will eventually run out of adjustment space. When this happens a simple solution is to replace the offending clamp. Contact us for a replacement, they are relatively cheap and will extend the life of your pole easily.

At a certain point your pole sections will have worn too much for even a replacement clamp to cure. When this happens a replacement pole (or sections thereof) will be the only answer.
 

© Gardiners Pole Systems

View more Window Cleaning Articles

Window Cleaning Resources

Copyright © 2010   Window Cleaning Resources    All rights reserved

Contact Us       Privacy Policy      Disclaimer 

Window Cleaning Resources was set up and went ‘live’ online in October 2006. Since then the site has rapidly grown in popularity, becoming a central reference point for window cleaners in the UK. The site is regularly visited by tens of thousands of window cleaners each month. Thanks to the support of our site sponsors we intend to continue developing Window Cleaning Resources to act as a catalyst for future growth and development within the window cleaning industry. If you would like to introduce a new product, service or idea to window cleaners, particularly in the UK, then we would glad to be of assistance in providing exposure to your target market.

Sponsorship Information